The table below includes all Tag's blink codes:
Event | Animation | Number of Blinks | Blink sequence [ms] | FW | Notes |
---|---|---|---|---|---|
Startup | 1 | 1780 | since 3.119 | Signalized only when the Tag is turning on. | |
Shutdown | 11 | 20-30-40-50-60-70-80-90-100- 110-120-130-140-150-160-170- 180-190-200-210-220 | since 3.119 | Signalized when the Tag is turning off. Shutdown is also signalized before switch to DFU mode. | |
Button push (in STD FW) | 1 | 3 | since 3.119 | ||
Button push (in DFU mode) | 3 | 50-50-50-50-50 | since 3.120 | ||
Factory reset | 5 | 190-180-170-160-150-140-130- 120-110 | since 3.119 | Tag was reset to the factory default configuration. | |
Switch to DFU mode | 32 | 32-32 down to 1-1 with 1ms step | since 3.120 | The tag was switched to Device Firmware Update mode | |
Corrupted setting | 5 | 100-100-100-100-100-100-100- 100-100 | since 3.119 | The tag received a new config, that is corrupted. | |
DWM initialization error | 6 | 222-100-100-100-100-100-100- 100-100-100-100 | since 3.119 | Unable to initialize communication with DWM error. It is signalized in infinite loop. | |
EEPROM/NFC error | 12 | 250-250-250-250-250-250-250- 250-125-125-125-125-125-125- 125-125-250-250-250-250-250- 250-250 | since 3.119 | It may be caused by a communication error. However, if the signaling is repeated in a loop, it is an HW error | |
Flash CRC error | 4 | 80-80-80-500-80-80-80 | since 3.119 | CRC stored in EEPROM do not match the CRC calculated - user setting is corrupted. | |
Low battery (cut off voltage) | 4 | 100-100-100-100-100-100-100 | since 3.119 | Once the battery is low, the tag signalize it and then switches to shutdown mode | |
Low battery (periodical signalization) | 10 | 20-20-20-20-20-20-20-20-20-20 -20-20-20-20-20-20-20-20-20 | since 3.125 | If the battery is running low, the tag can signalizes it periodically by this code. Optional feature. | |
New config received - NFC | 3 | 50-50-50-50-50 | since 3.119 | The tag received and applied new config via NFC. | |
New config received - UWB | 3 | 500-500-500-500-500 | since 3.119 | The tag received and applied new config via UWB. |